IstioHigh5xxErrorRate #
High percentage of HTTP 5xx responses in Istio (> 5%).
Alert Rule
alert: IstioHigh5xxErrorRate
annotations:
description: |-
High percentage of HTTP 5xx responses in Istio (> 5%).
VALUE = {{ $value }}
LABELS = {{ $labels }}
runbook: https://srerun.github.io/prometheus-alerts/runbooks/istio-internal/istiohigh5xxerrorrate/
summary: Istio high 5xx error rate (instance {{ $labels.instance }})
expr: sum(rate(istio_requests_total{reporter="destination", response_code=~"5.*"}[5m]))
/ sum(rate(istio_requests_total{reporter="destination"}[5m])) * 100 > 5
for: 1m
labels:
severity: warning
Here is a runbook for the Prometheus alert rule IstioHigh5xxErrorRate
:
Meaning #
The IstioHigh5xxErrorRate
alert is triggered when the percentage of HTTP 5xx responses in Istio exceeds 5% over a 5-minute period. This alert indicates that there is a high rate of internal server errors within the Istio service mesh, which can impact the overall reliability and performance of the system.
Impact #
The impact of this alert can be significant, as it may cause:
- Increased error rates and degraded user experience
- Decreased system reliability and availability
- Difficulty troubleshooting and debugging issues
- Potential revenue loss or business impact due to system downtime
Diagnosis #
To diagnose the root cause of this alert, follow these steps:
- Check the Istio dashboard and logs for any signs of component failures or errors.
- Verify that the Istio control plane is healthy and functional.
- Inspect the
istio_requests_total
metrics to identify the specific services or pods that are experiencing high error rates. - Check the application logs for any errors or exceptions that may be contributing to the high error rate.
- Verify that the underlying infrastructure is healthy and has sufficient resources (e.g., CPU, memory, disk space).
Mitigation #
To mitigate the impact of this alert, follow these steps:
- Identify and address any underlying component failures or errors in the Istio control plane or data plane.
- Check for any configuration issues or misconfigurations in the Istio setup.
- Implement circuit breakers or retries to handle temporary errors and prevent cascading failures.
- Scale out the Istio control plane or data plane components to handle increased traffic or load.
- Consider implementing additional monitoring and logging to gain more visibility into the system and detect issues earlier.