SPAGENT-MIB::spTemperatureArray4-5Status #
Temperature sensor trap
Variables #
- spSensorStatus
- spSensorValue
- spSensorLevelExceeded
- spSensorIndex
- spSensorName
- spSensorDescription
Definitions #
- spSensorStatus
- The current integer status of the sensor causing this trap to be sent
- spSensorValue
- The current integer value of the sensor causing this trap to be sent
- spSensorLevelExceeded
- The integer level that was exceeded causing this trap to be sent
- spSensorIndex
- The integer index of the sensor causing this trap to be sent
- spSensorName
- The name of the sensor causing this trap to be sent
- spSensorDescription
- The description of the sensor causing this trap to be sent
Here is a sample runbook for the SNMP trap description:
Meaning #
The SPAGENT-MIB::spTemperatureArray4-5Status trap indicates that a temperature sensor has exceeded a predefined threshold. This trap is generated by a sensor monitored by the SP Agent, and it provides detailed information about the sensor that triggered the trap.
Impact #
The impact of this trap depends on the specific sensor and its role in the system. A temperature sensor exceeding a threshold may indicate:
- Overheating equipment, which can lead to system crashes, data loss, or even physical damage.
- Cooling system failures or malfunctions.
- Environmental issues, such as high ambient temperatures or poor air circulation.
Diagnosis #
To diagnose the issue, follow these steps:
- Identify the sensor that triggered the trap using the
spSensorIndex
andspSensorName
variables. - Check the current temperature value using the
spSensorValue
variable. - Determine the threshold value that was exceeded using the
spSensorLevelExceeded
variable. - Verify the sensor’s status using the
spSensorStatus
variable. - Consult the sensor’s description using the
spSensorDescription
variable to understand its role in the system.
Mitigation #
To mitigate the issue, follow these steps:
- Investigate the cause of the temperature increase, considering factors such as equipment load, ambient temperature, and cooling system performance.
- Take immediate action to reduce the temperature, such as:
- Reducing system load or shutting down non-essential components.
- Improving air circulation or increasing cooling capacity.
- Scheduling maintenance or replacing faulty components.
- Verify that the sensor is functioning correctly and providing accurate readings.
- Adjust the threshold values or sensor configuration as needed to prevent false alarms or improve alarm sensitivity.
- Monitor the system closely to ensure the issue is resolved and does not recur.